My installation lacked an HS34 serial connector. So I built an adapter, with 25m and 25f, to carry power to the HS34. Then a 9 pin F connector for serial.
This allows the HS34 to be powered yet disconnected from DSAB during updates. I open the panel to insert the adapter, and also access the
D100 serial which I've placed nearby.
25M pin 4 to 25F pin 4
25M pin 17 to 25F pin 17 (and split to 9F pin 5)
25F pin 14 to 9F pin 2
25F pin 1 to 9F pin 3
25f pin 17 to 9F pin 5.
See page 7-12 of the Rev 5.3 D100 installation manual for details.
BMcCand (formerly CCCT) - cross country in N248CT